Abstract General Information


Título / Title

Efficacy of smartphone-based retinal photography by undergraduate students in screening and early diagnosing Diabetic Retinopathy

Introdução / Purpose

To evaluate the efficacy of retinal photography obtained by undergraduate students using a smartphone-based device in screening and early diagnosing diabetic retinopathy(DR)

Material e Método / Methods

We carried out an open prospective study with ninety-nine diabetic patients (194 eyes), who were submitted to an ophthalmological examination in which undergraduate students registered images of the fundus using a smartphone-based device. At the same occasion, an experienced nurse captured fundus photographs from the same patients using a gold standard tabletop camera system (Canon CR-2 Digital Non-Mydriatic Retinal Camera), with a 45º field of view. Two distinct masked specialists evaluated both forms of imaging according to the presence or absence of sings of DR and its markers of severity. We later compared those reports to assess agreement between the two technologies

Resultados / Results

Concerning the presence or absence of DR, we found an agreement rate of 84.07% between reports obtained from images of the smartphone-based device and from the regular fundus camera; Kappa: 0.67; Sensitivity:71.0% (Confidence Interval [CI]:65.05% -78.16%); Specificity:94.06% (CI:90.63%-97.49%); Accuracy:84.07%; Positive Predictive Value (PPV): 90.62%; Negative Predictive Value (NPV): 80.51%. As for the classification between proliferative diabetic retinopathy and non-proliferative diabetic retinopathy, we found an agreement of 90.00% between the reports; Kappa:0.78; Sensitivity: 86.96%; (CI: 79.07% - 94.85%); Specificity:91.49% (CI: 84.95% - 98.03%); Accuracy:90.00%; PPV:83.33%; NPV:93.48%. Regarding the degree of classification of DR, we found an agreement rate of 69.23% between the reports; Kappa: 0.52. As relating to the presence or absence of hard macular exudates, we found an agreement of 84.07% between the reports; Kappa: 0.67; Sensitivity:71.60% (CI:65.05% -78.16%); Specificity:94.06% (CI: 90.63% - 97.49%); Accuracy: 84.07%; PPV:90.62%; NPV:80.51%.

Discussão e Conclusões / Conclusion

The smartphone-device showed a good accuracy in the detection of DR (84.07%)

Palavras Chave

Diabetic retinopathy; Retina; Early Diagnosis; Telemedicine; Ophthalmological Diagnosis Techniques; Low Cost Technology

Area

CLINICAL RETINA

Institutions

Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo - São Paulo - Brasil

Authors

João Pedro Romero Braga, Jéssica Deponti Gobbi, Moises Moura Lucena, Victor Bellanda, Miguel Frasson, Daniel Ferraz, Victor Koh, Rodrigo Jorge